You are here: Home » Products » MWM Spare Parts » Mass-impregn.cable 12142006 for MWM TCG2020 Gas Engine

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Mass-impregn.cable 12142006 for MWM TCG2020 Gas Engine

5 0 Reviews
Description: Mass-impregn.cable.

MWM part number: 1214 2006,1214-2006,12142006.

Suitable engine model: TCG2020V20,TCG2020V16K,TCG2020V12,CG170-20,CG170-16K,CG170-12.

 
Price: $ 15.17
  • WY12142006

  • Weyeah

  • 12142006

  • TCG2020

  • 0.058

  • 2-3 weeks

SKU:
Availability:
Quantity:
Product Description

The mass-impregnated cable (often referred to as mass-impregnated or mass-impregnated cable) for the MWM TCG2020 gas engine is a specialized electrical cable designed to provide reliable power transmission and resistance to high temperatures and environmental conditions within the engine’s electrical system. Here’s a detailed description of the mass-impregnated cable:

Mass-Impregnated Cable for MWM TCG2020 Gas Engine

Purpose:

  • Power Transmission: The mass-impregnated cable is used to transmit electrical power between various components of the engine, such as sensors, actuators, and control units.
  • Durability: Designed to withstand the harsh conditions found in engine compartments, including high temperatures, vibrations, and exposure to chemicals or moisture.
  • Reliability: Ensures consistent electrical performance and prevents power loss or signal interference that could affect engine operation.

Design Features:

  • Insulation:

    • Material: The cable typically features insulation that is impregnated with a special material to enhance its thermal resistance and mechanical durability. Common insulating materials include silicone, fluoropolymers, or other high-temperature-resistant compounds.
    • Impregnation: The impregnation process involves treating the insulation with a substance that improves its resistance to heat and environmental factors, ensuring the cable remains functional in the demanding conditions of an engine compartment.
  • Conductors:

    • Material: The conductors inside the cable are usually made from copper or aluminum, chosen for their excellent electrical conductivity and durability.
    • Stranding: The conductors may be stranded to improve flexibility and reduce the risk of breakage under vibration or movement.
  • Shielding:

    • Type: Some mass-impregnated cables include shielding to protect against electromagnetic interference (EMI) and ensure stable signal transmission.
    • Material: Shielding may be made from materials such as foil or braided wire, depending on the application requirements.
  • Temperature Rating:

    • High-Temperature Resistance: The cable is designed to operate effectively at high temperatures commonly encountered in engine compartments, often rated for temperatures up to 150°C (302°F) or higher.
  • Flexibility:

    • Design: Engine cables are designed to remain flexible despite high temperatures and vibrations, allowing them to be routed through tight spaces and withstand engine movement.
  • Protective Covering:

    • Material: The outer jacket of the cable is often made from a durable material that provides additional protection against abrasion, chemicals, and environmental exposure.
    • Type: The covering may be made from materials such as PVC, rubber, or high-temperature-resistant compounds.

Installation:

  • Routing: Route the cable carefully to avoid contact with sharp edges, hot surfaces, or moving parts. Proper routing is essential to prevent damage and ensure reliable operation.
  • Connections: Connect the cable according to the engine’s wiring diagram or service manual. Ensure that all connections are secure and properly insulated to avoid electrical shorts or disconnections.
  • Protection: Use cable ties, clamps, or conduit to secure the cable and protect it from physical damage and environmental factors.

OEM vs. Aftermarket:

  • OEM (Original Equipment Manufacturer): OEM mass-impregnated cables are designed to meet the exact specifications of the MWM TCG2020 engine, ensuring compatibility and reliability.
  • Aftermarket: Aftermarket cables can be more cost-effective but should be selected based on their specifications to ensure they meet or exceed the performance and durability of OEM cables.

Example Specifications:

  • Insulation Material: High-temperature-resistant materials such as silicone or fluoropolymers.
  • Conductor Material: Copper or aluminum.
  • Temperature Rating: Typically up to 150°C (302°F) or higher.
  • Shielding: May include foil or braided wire for EMI protection.
  • Outer Jacket: Durable materials such as PVC or rubber for additional protection.

For precise part numbers, dimensions, and specifications, consult the MWM TCG2020 service manual or contact a professional to ensure you select and install the correct mass-impregnated cable for your engine’s needs.

Previous: 
Next: 

Product Category

Contact Us

 +86-18064047867
 info@weyeahengine.com
 1st Floor, Building 3, No. 6 Songgang Road, Panlongcheng Economic Development Zone, Huangpi District, Wuhan, China

Related News

Inquiry

Quick links

Leave a Message
Contact us

Product category

Contact us

 +86-18064047867
 info@weyeahengine.com
 1st Floor, Building 3, No. 6 Songgang Road, Panlongcheng Economic Development Zone, Huangpi District, Wuhan, China

Global after-sale service hotline:

+86-18064047867

Complaints and suggestions:

Wuhan Weyeah Power Machinery Co., Ltd. All rights reserved. Supported by leadong. Sitemap.
GE Jenbacher, MWM, Caterpillar, Deutz, MAN B&W, MTU, Wartsila are registered trademarks owned by their manufacturers.