You are here: Home » Products » MWM Spare Parts » Relay 12320854 for MWM TCG2020 Gas Engine

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Relay 12320854 for MWM TCG2020 Gas Engine

5 0 Reviews
Description: Relay.

MWM part number: 1232 0854,1232-0854,12320854,

1229 8442,1229-8442,12298442.

Suitable engine model: TCG2020V20,TCG2020V16K,TCG2020V12,CG170-20,CG170-16K,CG170-12.

 
Price: $ 201.11
  • WY12320854

  • Weyeah

  • 12320854

  • TCG2020

  • 0.05

  • 2-3 weeks

SKU:
Availability:
Quantity:
Product Description

The relay for the MWM TCG2020 gas engine is an electrical component that plays a crucial role in the engine's electrical system. Relays are used to control high-current circuits with a low-current signal, ensuring proper functioning and protection of various electrical systems and components. Here’s a detailed description:


Relay for MWM TCG2020 Gas Engine

Purpose:

  • Control High-Current Loads: Relays are used to switch high-current loads, such as starter motors, fuel pumps, or other heavy electrical components, using a low-current control signal. This helps protect sensitive switches and control circuits from high current.
  • Switching Functions: Relays enable the control of electrical systems in the engine, such as ignition, fuel injection, or cooling fans, by responding to signals from the engine control unit (ECU) or other control systems.
  • Protection: They provide electrical isolation between the control circuit and the load circuit, helping to protect the engine’s electronic systems from potential damage due to high current or voltage spikes.

Design Features:

  • Contacts:

    • Normally Open (NO): The relay contacts are open when the relay is not energized and close when the relay is activated, allowing current to flow through the load circuit.
    • Normally Closed (NC): Some relays have normally closed contacts that are closed when the relay is not energized and open when the relay is activated, used for different switching requirements.
  • Coil:

    • Control Circuit: The relay coil is energized by a low-current control signal, causing the relay to switch the high-current load circuit on or off. The coil is typically powered by the engine’s electrical system or ECU.
  • Housing:

    • Encased: Relays are usually encased in a durable plastic or metal housing to protect the internal components from environmental factors such as moisture, dust, and vibration.
    • Mounting: Designed for easy mounting in the engine’s electrical system, often with standard connectors or mounting brackets.
  • Connections:

    • Terminals: Equipped with terminals or connectors for wiring the control and load circuits. The relay will have clearly marked terminals for the coil and the switch contacts.
  • Specifications:

    • Voltage Rating: The relay must be rated for the voltage of the engine’s electrical system, typically 12V or 24V for automotive applications.
    • Current Rating: The relay must be capable of handling the maximum current required by the load it controls. This is specified in amps and ensures the relay can handle the electrical load without overheating or failing.

Installation:

  • Wiring: Connect the relay according to the engine’s wiring diagram or schematic. Proper connections are essential for reliable operation and to avoid electrical issues.
  • Mounting: Install the relay in a location where it is secure and protected from excessive heat or vibration. Ensure it is properly mounted to avoid damage or disconnection.
  • Testing: After installation, test the relay to ensure it operates correctly and that the controlled systems function as intended.

OEM vs. Aftermarket:

  • OEM (Original Equipment Manufacturer): OEM relays are designed to meet the specific requirements of the MWM TCG2020 engine, ensuring compatibility and reliability. They are recommended for their quality and adherence to the engine’s specifications.
  • Aftermarket: Aftermarket relays can be more cost-effective but should be selected based on their specifications to ensure they meet the same quality and performance standards as OEM parts.

Example Specifications:

  • Voltage Rating: Typically 12V or 24V, depending on the engine’s electrical system.
  • Current Rating: Rated in amps, suitable for the load requirements of the engine’s electrical components.
  • Contact Configuration: Typically includes Normally Open (NO) and possibly Normally Closed (NC) contacts, depending on the application.

For exact part numbers, dimensions, and specifications, refer to the MWM TCG2020 service manual or consult with a professional to ensure you select the correct relay for your engine’s electrical system.

Previous: 
Next: 

Product Category

Contact Us

 +86-18064047867
 info@weyeahengine.com
 1st Floor, Building 3, No. 6 Songgang Road, Panlongcheng Economic Development Zone, Huangpi District, Wuhan, China

Related News

Inquiry

Quick links

Leave a Message
Contact us

Product category

Contact us

 +86-18064047867
 info@weyeahengine.com
 1st Floor, Building 3, No. 6 Songgang Road, Panlongcheng Economic Development Zone, Huangpi District, Wuhan, China

Global after-sale service hotline:

+86-18064047867

Complaints and suggestions:

Wuhan Weyeah Power Machinery Co., Ltd. All rights reserved. Supported by leadong. Sitemap.
GE Jenbacher, MWM, Caterpillar, Deutz, MAN B&W, MTU, Wartsila are registered trademarks owned by their manufacturers.